User's Manual

Table Of Contents
Start-up Manual
44 04043988 - 02/2014 B-eco
6.2 Network access requirements
An Ethernet network is used for startup and maintenance of the terminal as well as
communication in production use.
To guarantee unhindered and trouble-free data traffic, the UDP ports used for
communication must be free.
Modify the firewall configuration accordingly.
6.2.1 Communication
The UDP port used for communication between B-COMM and the terminal must be
free.
The UDP port is located in the range of 7700 hex to 77EF hex (30464 dez. to 30703
dez.) depending on the configuration.
If communication is established via http/https, the port used must be free (normally
port 80 or 8080).
6.2.2 Comparing finger templates
Devices with a biometric CBM reader require another UDP port for exchanging
biometric data.
The UDP port used for the FTCS or BCFTC stream must be free.
The UDP port is located in the range of 7800 hex to 78EF hex (30720 dez. to 30959
dez.) depending on the configuration.
6.2.3 1-click installation
It must be possible to transfer UDP data packages unhindered to the B-COMM server.
IP address 239.255.255.250, UDP port 1900 dez. and UDP port 7900
(30976 dez.) must be free.
The SSDP service has to be enabled in the Windows service management.
The FTP connection over standard port 21 must be free.
6.2.4 Configuration
The terminal is configured by means of the service module. Standard port 80 is used
for access with an http browser.
Standard port 21 is used for the FTP connection to the terminal.