Manual Installation
B-eco 04043988 - 02/2014 37
5.4 Inserting batteries
Only devices with UPS!
Before commissioning the device, the batteries for the uninterruptible power supply
(UPS) must be inserted.
A blister pack containing 6 batteries is included in the delivery of the device.
Specification: NiMH battery, 1.2 V, capacity min. 2000 mAh, size AA
NOTICE
Wrong battery types or incorrectly inserted batteries can overheat and damage the
device.
• Use new identical batteries conforming to the above specification only.
• Do not use any primary battery cells.
• Ensure correct polarity.
• Remove the TORX8 screw (arrow).
• Remove the cover of the battery compartment.
• Press batteries into the holding clamps.
• Re-attach cover.
After an operating time of about 10 hours, the batteries are completely charged,
and the UPS is ready for use.