5.4 Inserting batteries
Only devices with UPS!
Before commissioning the device, the batteries for the uninterruptible power supply
(UPS) must be inserted.
A blister pack containing 6 batteries is included in the delivery of the device.
Specification: NiMH battery, 1.2 V, capacity min. 2000 mAh, size AA
NOTICE
Wrong battery types or incorrectly inserted batteries can overheat and damage the
device.
Use new identical batteries conforming to the above specification only.
Do not use any primary battery cells.
Ensure correct polarity.
Remove the TORX8 screw (arrow).
Remove the cover of the battery compartment.
Press batteries into the holding clamps.
• Re-attach cover.
After an operating time of about 10 hours, the batteries are completely charged,
and the UPS is ready for use.