Manual Start-up
B-eco 04043988 - 02/2014 47
6.5 Configuration-specific settings
In the following, we present the required settings for various device configurations.
The settings can be made using service functions in the menus of the service mode,
see BECO service module manual.
It is also possible to transfer the parameters in the reboot.cmd file via FTP to the
device, see BECO service module manual.
The following parameter examples correspond to the entries in this file.
6.5.1 Ethernet settings
These settings are required if the terminal is integrated into an Ethernet network. For
details, please see the BECO service module manual.
6.5.1.1 Assigning fixed terminal network parameters
[Ethernet]
DHCP Mode=disabled
Terminal Addr=10.10.5.85
Netmask=255.255.0.0
Gateway Addr=10.10.1.101
DNS Configuration from DHCP=disabled
DNS Addr=0.0.0.0
6.5.1.2 Assigning terminal network parameters via DHCP
[Ethernet]
DHCP Mode=enabled
DNS Configuration from DHCP=disabled
DNS Addr=0.0.0.0
6.5.1.3 Requesting DNS settings via DHCP
[Ethernet]
DHCP Mode=enabled
DNS Configuration from DHCP= enabled