User's Manual

Table Of Contents
Mounting and Installation Manual B-Net® 91 04
24 © Kaba GmbH 12/2008
Baud Rate
The baud rate of the RS-485 subpartyline can be set by means of switch 8.
The remaining transmission parameters are fix.
7 data bits, even parity, 1 stop bit, response control 3 seconds, operation
monitoring 3.5 seconds
Switch 8 Baud Rate
on 19200 (standard)
off 9600
BPA/9 protocol
The BPA/9 protocol can be switched off by means of switch 9.
Switch 9 BPA/9 protocol
on BPA/9 protocol (standard)
off no protocol
DIP switch
All DIP switches can be deactivated by means of switch 10. The parameters are set
in the system mode (see chapter
7) by means of the "LOWPAR" command.
Switch 10 DIP switch
on ON (standard)
off Off
5.9.1 Required DIP switch settings in different operating modes
Online mode:
Switch 1 2 3 4 5 6 7 8 9 10
Device address Group address on on on
Stand-alone operation
Switch 1 2 3 4 5 6 7 8 9 10
Device address Group address on on on