User's Manual

Table Of Contents
Manual B-Net® 91 04 System mode
12/2008 © Kaba GmbH 39
Additional parameters with protocol type 02:
Header Length
Up : '00' : 00
Down : '00' : 00
>_
7.1.4.1 Description of the Parameters
Serial interface:
5 digits: Baud rate (01200 to 76800)
1 digit: Number of data bits (7, 8)
1 digit: Parity (0 or N = no; 1 or O = odd; 2 or E = even)
1 digit: Number of stop bits (1, 2)
BPA/9:
2 digits: Group number (00 to 29)
2 digits: Device number (00 to 59)
1 digit: Polling (0) or contention mode (1)
1 digit: Quick call (0 or 1)
1 digit: Additional end character (0 or 1)
3 digits: Response timeout (001 to 999 = 0.1 – 99.9 sec.)
3 digits: Operating timeout (001 to 999 = 0.1 – 99.9 sec.)
3 digits: Transmit delay (000 to 999 = 0.0 – 99.9 sec.)
Header Up/Down:
2 digits: Header when sending (00 to 05)
2 digits: Header when receiving (00 to 05)
Remark
The parameters for "serial interface" as well as GID and DID can only be changed
using the LOWPAR command if the DIP switch 10 is set to OFF, see chapter
5.9.