Manual B-Net® 91 04 Product Description
12/2008 © Kaba GmbH 9
3.1 Technical data
• Operating voltage: 12 – 32 V DC / 16 – 27 V AC
Power supply
• Current
consumption:
max. 150 mA at 24 V
Interface
• RS-485 2-wire subpartyline
Protocol: BPA9; transmission parameters: 9600/19200 baud, 7 data bits, parity
even, 1 stop bit
Other settings via system mode are possible.
Output
• 1 relay output, contact load 30 V AC/DC, max. 1 A
Readers
• LEGIC® reader
Reading and writing of LEGIC® media.
Data retention in
case of power failure
• Modified parameters, list of badges, etc. are stored in non-volatile memory
(EEPROM) and are retained when a power failure occurs.
• Protection class according
to IEC 60529:
IP66 with connecting cable
IP54 with terminal board
Environmental
conditions
• Environmental temperature: - 25° C - + 55° C
Environmental class: 4
• National Electrical Manufacturers Association (NEMA) 4
Dimensions
Dimensions in mm
45
90
21
Ø10
Ø3,5
77
93
77
48 11