Installation Technical Manual
46 - 06/2016 Kaba Remote Reader 91 15-AM (US/
CAN)
5.5.3 Output
The function of the inputs and outputs depends on the control unit used and its pa-
rameter settings.
Output (OUT), e.g. for an electric strike:
COM
NC
1
NO
2
1 Kaba Remote Reader 91 15
2 Free-wheeling diode for door openers with DC voltage
or
varistor for door openers with AC voltage.
Item* Meaning
6 NC (normally closed)
6 COM
6 NO (normally open)
*See
Contact load capacity: See Outputs
Also see about this
2 5.5.1Connections [}43]
5.5.3.1 Note on the use of door openers
The relay can be used to activate the door opener. For door openers that are sup-
plied with DC voltage, a "free-wheeling" diode must be parallel-connected (in the re-
verse direction) to the door opener for noise attenuation. A varistor must be con-
nected parallel to AC voltage door openers.