55- 06/2016Kaba Remote Reader 91 15-AM (US/
CAN)
• If the Remotereader no longer needs to read read-protected segments of a
medium
In this chapter, the term "Write authorization" will be used for the terms "Write au-
thorization" and "Read authorization".
In this chapter, the term "Writing right" will be used for the terms "Writing right" and
"Reading right".
6.3.1 Cancel all writing rights granted by a write authorization
1. Reset remote reader to the basic status, see Chapter
6.3.2 Cancel a particular writing right granted by a write authorization:
Use the SAM 64 card to delete the relevant stamp.
The signaling is carried via the registration unit on which the card is presented.
Requirements
• In order to cancel the write authorization, a SAM 64 card with the relevant seg-
ment range is required.
• The Remotereader should be in regular operation and waiting for an RFID entry.
Procedure
1. Present the SAM 64 card to the connected registration unit without interruption
(approx. 15s).
ð The Registration unit illuminates green during the process.
ð 3x beep: Write-authorization canceled
If the write authorization has already previously been canceled with the
same SAM 64 card, this will be signaled immediately with 3x beeps.
ð No signaling: Write authorization has not been canceled.
Possible reasons
- The SAM 64 card was removed from the RFID field too early
- ISO 14443A is not activated in the system
- If SAM+ media are being used: No credit is available
2. Remove the SAM 64 card from the field.