User's Manual

Table Of Contents
Technical Manual Start-up
55- 06/2016Kaba Remote Reader 91 15-AM (US/
CAN)
If the Remotereader no longer needs to read read-protected segments of a
medium
In this chapter, the term "Write authorization" will be used for the terms "Write au-
thorization" and "Read authorization".
In this chapter, the term "Writing right" will be used for the terms "Writing right" and
"Reading right".
6.3.1 Cancel all writing rights granted by a write authorization
1. Reset remote reader to the basic status, see Chapter
6.3.2 Cancel a particular writing right granted by a write authorization:
Use the SAM 64 card to delete the relevant stamp.
The signaling is carried via the registration unit on which the card is presented.
Requirements
In order to cancel the write authorization, a SAM 64 card with the relevant seg-
ment range is required.
The Remotereader should be in regular operation and waiting for an RFID entry.
Procedure
1. Present the SAM 64 card to the connected registration unit without interruption
(approx. 15s).
ð The Registration unit illuminates green during the process.
ð 3x beep: Write-authorization canceled
If the write authorization has already previously been canceled with the
same SAM 64 card, this will be signaled immediately with 3x beeps.
ð No signaling: Write authorization has not been canceled.
Possible reasons
- The SAM 64 card was removed from the RFID field too early
- ISO 14443A is not activated in the system
- If SAM+ media are being used: No credit is available
2. Remove the SAM 64 card from the field.