Technical Manual Maintenance
57- 06/2016Kaba Remote Reader 91 15-AM (US/
CAN)
7.3 Factory Reset/Reset Device to the Basic Status
Consequences of the factory reset
• The device is returned to its basic state (factory settings).
• The parameter settings are deleted.
• The stamps are deleted.
• The factory reset lasts approximately 3seconds.
• The access point is blocked during the factory reset.
Procedure Signaling
Remote reader
Signaling
Registration unit
1. Disconnect the device from the power supply.
• The access point is blocked during the factory re-
set.
2.
Set DIP switch 6 to ON.
(Switching the DIP switch when the power supply is
connected has no effect).
3. Connect the device to the power supply.
After the registration unit
beeps, all LEDs flash or-
ange
2 x short beep, then red/
green flashing
• Device is reset to the factory settings (for further
effects, see above, consequences of the factory
reset).
4. Disconnect the device from the power supply.
5.
Set DIP switch 6 to OFF.
6. Connect device to the power supply.
• The device is in operation again.
• In the event of online connection: The host con-
trol device loads the current parameters on the
remote reader.
• The access point is ready for bookings.
State: permanent green
or
flashing green
or
flashes alternating green/
orange
permanent green