3.2.6 Power supply
For the power supply of the device, the following alternatives are possible:
PoE (Power over Ethernet)
Mains power input (docking station with BEX120 motherboard required)
24 V DC power supply (docking station with BEX121 motherboard required)
PoE (Power over Ethernet)
Power supply of the terminal via the 8-wire Ethernet cable (max. 100 m)
In accordance with IEEE802.3at/type 1 class 0 (0,44-12,95 W)
Supported feed processes: Spare pair feed and phantom feed
Mains voltage input
Voltage range: 100–240 V AC
Frequency: 50/60 Hz
Current consumption: max. 200 mA
24 V DC power supply
Voltage range: 22–30 V DC
Current consumption: max. 1 A
Only power supply units that fulfil the following requirements may be used for power supply:
LPS (Limited Power Source) and SELV (Safety Extra Low Voltage) in accordance with IEC/
EN/UL/CSA 60950-1 or ES1 and PS2 in accordance with IEC/EN/UL/CSA 62368-1.
3.2.7 Uninterruptible power supply
UPS510 (option)
The UPS510 consists of an electronic part with charging circuit and a rechargeable battery.
The components are housed in a self-contained housing. Uninterruptible operation of the
device in case of power supply failure is ensured by an NiMH battery with a capacity of 2100
mAh. The battery is fully charged after a charging time of 10 hours.
The UPS510 ensures operation in case of power supply failure for up to 30 minutes or approx.
200 bookings, whatever occurs first.
Condition: New battery, 100% charged, temperature 20 ° - 25 °C.
3.2.8 Ambient conditions
Ingress protection according to IEC 60529
IP20 (devices with swipe reader)
IP40 (devices with RFID and CBM readers)
Prerequisite: Cable entry from below using the enclosed grommets
Relative humidity
5% - 85%, non-condensing
Ambient temperature
-5 °C – +45 °C (operation without UPS)
0 °C – +40 °C (operation with UPS)
-25 °C – +70 °C (storage without UPS)