5 Installation
5.1 Installation conditions
5.1.1 General
An accurate installation of all components is a basic requirement for a properly functioning
device. The following installation instructions must be adhered to.
5.1.2 Installation site
Distances
RFID fields which are close together can influence one another, thereby reducing the reading
and writing distances. An all-round clearance of 20 cm must be maintained between two
devices with RFID readers.
Mounting height
Recommended mounting height 140 cm to the top edge of the terminal.
Electromagnetic fields
Do not install the device in the vicinity of strong electromagnetic fields caused, for example,
by switched-mode power supplies, electric power lines, phase control etc. Electromagnetic
fields can adversely affect read performance or cause malfunctions, especially in the case of
contactless RFID readers.
Electromagnetic fields may impair the touch screen functions.
Sun irradiation
Direct sun irradiation leads to reflections within the display area (resulting in poor readability
of the display.)
Direct sun irradiation may impair the function of the biometric reader.
Direct sun irradiation may impair the function of the proximity sensors.
Avoid installation at places with direct sun irradiation.
5.1.3 Connections
The following connectors must have been prepared at the installation site of the terminal:
Power supply for the terminal
Ethernet network (in case of host communication via Ethernet)
Signal lines to inputs/outputs (optional).