42 04043552 - 07/2017Terminal 97 00
5.1.4 Power supply
5.1.4.1 PoE power supply
For PoE power supply [}3.2.6], a PSE (Power Sourcing Equipment) must be provided on the
network cable for power feeding.
Possible methods for feeding the power supply via the PSE:
End span (direct supply, e.g. via PoE switch)
Midspan (supply via intermediate sources, e.g. PoE injector)
5.1.4.2 24 V DC power supply
Devices with docking station equipped with BEX121 motherboard. It has a 24 V DC input with
overvoltage protection and transient filter for supplying power to the terminal.
Only power supply units that fulfil the following requirements may be used for power supply:
LPS (Limited Power Source) and SELV (Safety Extra Low Voltage) in accordance with IEC/
EN/UL/CSA 60950-1 or ES1 and PS2 in accordance with IEC/EN/UL/CSA 62368-1.
5.1.4.3 Mains voltage supply
Only devices with docking station equipped with BEX120 motherboard. It has a 100-240 V AC
mains voltage input and an integrated limited power source power supply unit (LPS).
The mains voltage supply can be designed as stationary wiring or as separable connection.
For the terminal, a separate fuse-protected circuit must be provided. If the mains voltage
supply is designed as a separable connection, the following applies:
The mains socket with grounded contact must be in the immediate vicinity of the device.
The mains plug must be freely accessible.
If the mains voltage supply is designed as stationary wiring, the following applies:
An easily accessible circuit breaker must be provided.
The circuit breaker (LS) must be designed for max. 10 A.
The electrical system of the building must be equipped with an all-pole supply circuit
switch.