InstallationTechnical Manual
4704043552 - 07/2017 Terminal 97 00
5.4.3 Mains fuses
Only devices with BEX120 motherboard!
The mains fuses are located under the sheet metal cover (1). Remove the cover in the follow-
ing way:
ΓΌ The mains power supply is off.
1. Unscrew the screw (2), TORX T10.
2. Unscrew the M4 nut (3) using a wrench with size 7.
3. Push the sheet metal cover (1) slightly upwards (unhinge it) and remove it
The mains voltage is secured with fuses on 2 poles.
The fuses (4) are of the plug-in type and can be easily replaced.
4 = 2x subminiature fuse (radial) T 1.0 A/250 V, order number 04037221
The fuses may only be replaced with fuses of the same type.