User's Manual
Table Of Contents
- Table of Contents
- 1 About this document
- 2 Basic safety information
- 3 Product description
- 4 Construction and function
- 4.1 Device structure
- 4.2 Product versions
- 4.3 Terminal software
- 4.4 System connection
- 4.5 Authentication types
- 4.6 CardLink
- 5 Installation
- 6 Commissioning
- 7 Operation
- 8 Maintenance
- 9 Packaging/Returns
- 10 Disposal
- Index
![](/manual/dormakaba-ead/legmrd/user-s-manual-english-french/images/img-31.png)
InstallationTechnical Manual
4904043552 - 07/2017 Terminal 97 00
5.4.5 Digital inputs
Only devices with optional motherboard and B-Client HR30 ‘Door control’ software option.
4 digital inputs are available. The inputs can be used for a door opener key, access control or a
customized application.
Assignment of inputs E1 to E4 depends on the configuration.
The inputs can be controlled by a simple switch or a relay contact. The corresponding input is
connected to common ground. An open input is recognized as ‘high’ due to the internal pull-up
resistor. Ground potential equals ‘low’.
Level
High = + 4.5 V to + 30 V or open
Low = - 30 V to + 1.5 V
Assignment/switching conditions (B-Client HR30)
Input Function Open/High Ground/Low
E1 Door frame contact Door open Idle state
E2 Door-opener push but-
ton
Idle state Door opens (relay 2)
E3 Block terminal Idle state Terminal blocks
E4 - - -
Principle