User's Manual

Manual Operation
6.1.1.1 Enroll a person
After pressing key 1 (for option 1) the administrator is prompted to enter the
enrollment ID, typically the personnel number. Then the biometric module (its red
light) is activated. The two fingers (e. g. the right and left forefinger) are read 3 times
each to guarantee high quality templates. For better user guidance an image of the
scanned finger is shown in a white field. As soon as a green frame appears around
this field, the scan has been successful.
If the finger is not placed correctly the user is prompted to move the finger up, down,
left, right, press harder etc.
The red light turns off and on again after each successful read operation. A message
is shown if the enrollment of the two templates has been successful. In case of an
error the user has to repeat the enrollment steps.
6.1.1.2 Delete a person
By selecting option 2 – Delete person – the administrator can delete the templates
for a certain user on the basis of his ID.
After pressing key 2 the administrator is prompted to enter the ID. After that he has
to answer a confirmation prompt. Only if he confirms with the OK key, the templates
for this ID are deleted from the Sagem module.
6.1.1.3 Delete all
By selecting option 3 – Delete All – the administrator can delete all templates stored
in the Sagem module. This option corresponds to the web interface parameter
„Delete all templates" on the page „Fingerprint“ of the reader parameter group. It is
recommended to act with caution when using this option, because there is no way to
recover the content of the Sagem module and all users have to re-enroll after the
delete. Therefore the administrator is prompted twice to confirm the deletion of all
templates in the module.
TT1100 04044239 - 08/2013 65