User's Guide

dormakaba USA Inc. System User Guide 7040.0320 | 8
2.2 System Components
Each system may differ depending on customer requirements. The sub-sections outlined below cover the full suite of the LA GARD
safe lock system.
2.2.1 Keypad
The Keypad comes in two varieties: Display and non-Display. The Display variant shows messages on screen while the non-Display
version implements a series of LED flashes and beeps for messages. The Keypad is the user interface for the entire system. Refer to
the Keypad Installation Guide (Document #7033.0320) for more information.
2.2.2 Multiplexer
The Multiplexer is used in multi-lock systems and allows multiple safe locks to connect with the Keypad. Refer to the Multiplexer
Installation Guide (Document #7038.0320) for more information. The Multiplexer is not UL evaluated.
2.2.3 Safe Lock
The safe lock is either a dead bolt, a spring bolt or a swing bolt, that locks and unlocks when the Keypad receives correct user
credentials. This lock system comes in many varieties depending on the application. Refer to the Safe Lock Installation Guide
(Document #7034.0320) for more information.
2.2.4 AC Adapter
The AC Adapter can be used to power the System where batteries alone would not be appropriate. Refer to the AC Adapter
Installation Guide (Document #7037.0320) for more information.
2.2.5 Battery Box
The Battery Box can serve as the secondary power source to the LA GARD System. Refer to the Battery Box Installation Guide
(Document #7035.0320) for more information. The Battery Box is not UL evaluated.
2.2.6 Alarm Box
The Alarm Box is a hard-wired external alarm device. If used, the Alarm Box must be plugged into the BAT port of Lock #1. The Alarm
Box allows for a remote disable input that can block the open command to the lock if asserted. Refer to the Alarm Box Installation
Guide (Document #7036.0320) for more information. The Alarm Box is not UL evaluated.
2.2.7 Reset Box
The Reset Box, when attached to a lock BAT port will remove users and resets the Master Combination on LA GARD safe locks. The
lock being reset should be disconnected from the Keypad and must power up from a battery within the Reset Box. The Reset Box
LED will light when the reset function is performed. If a lock is already reset, applying the Reset Box will not light the LED.
The Reset Box will only work in conjunction with LA GARD safe locks with a BAT port (will not work with older model LG BASIC Series
locks). Refer to the Reset Box User Guide (Document #7039.0320) for more information. The Reset Box is not UL evaluated.
2.2.8 Fob
The Fob is used as a secondary Bluetooth® credential to user’s combination. The fob can be enrolled at the Model 700 Keypad and
assigned to a user.
For UL 2058 compliance, the fob credential was not evaluated by UL. However, if a fob credential is employed, it’s required to be
accompanied by a user combination to open a lock. The fob cannot be used as sole means to operate and open the lock.