User's Guide
dormakaba USA Inc. System User Guide 7040.0320 | 19
b. Navigate through the information on screen with the arrow buttons
4. During a Holiday, the lock will not open at any time on the specified day(s). To view holiday(s), do the following:
a. Select View Holiday
b. Navigate through the information on screen with the arrow buttons
Note: If Time/Date is not set after a prolonged power outage, access time lock schedules cannot be enforced and may result in the
inability to open the lock until the time/date is set.
3.8 Users
3.8.1 Lock User Types
There are three types of users, each with different capabilities. The sub-sections outlined below cover each Lock User Type and their
respective functions.
3.8.1.1 Master
• There will always be 1 Master User per safe lock
• Combination length is always 8 digits and is not modified by the combination length system setting
• The default factory combination is 1-2-3-4-5-6-7-8
• The User ID is always 00 and cannot change
• Cannot open the lock directly
• Can change their combination either via the Keypad or the LA GARD Software client
• Needs to authenticate with an old combination prior to being allowed to update their combination
• The forced-change-on-first-use rule does not apply to Master combinations
• The Master combination should be changed from the default value prior to adding any other non-Master Users to the System
3.8.1.2 Manager
• Should be enabled within the system, but not required
• Multiple Managers may be defined depending on the lock type
• Only Master-authenticated users can modify the Manager’s settings
• The combination is in the format of 2 ID digits plus 6 to 9 combination digits
• The combination length required for the system applies to Manager(s) and all other users
• The combination length will be the same for all Users in the system, including Manager(s)
• May change their combination via the Keypad
• May open the lock if the access settings are enabled for the lock
• May set other access Users’ one-time-combo via the Keypad menus or via the LA GARD Software client
• May be granted Time Delay Override if Time Delay option is applied to a safe lock