4 Construction and function
4.1 Device layout
14
13 91012 11
1
15
2 43
5
6
7
8
Factory
Reset
1 RS-232 ports A + B
2 RS-485 port for connecting readers
3 Jumper for RS-485 bus connection
4 Connections for registration units
5 Status LED
6 IN-LEDs
7 OUT-LEDs
8 Connection for extension modules
9 Connection for the power supply
10 Outputs
11 Inputs
12 Input for connecting a tamper switch
13 Ethernet port
14 Ethernet LEDs
15 Reset button