User's Manual

Installation Technical Manual
28 04047408 - 10/2020dormakaba access manager 92 00 9200-K7 TP4-Client
5 Installation
5.1 Installation requirements
5.1.1 General
An accurate installation of all components is a basic requirement for a properly functioning
device. The following installation instructions must be adhered to.
5.1.2 Installation location
The product is designed for the stationary use in buildings. The product is not suitable for the
use in vehicles.
The access manager is mounted on a top hat rail in a housing or IT rack.
The access manager should be installed in a location where it is safe from tampering within
the area being secured.
The mounted height for the terminal should not be higher than 2 meters.
Electromagnetic fields
Do not install the device in the vicinity of strong electromagnetic fields caused, for example,
by switched-mode power supplies, electric power lines, phase control etc.
5.1.3 Connections
The following connections must be present at the installation location:
Ethernet cable, with RJ45 plug
Power supply cable
Lines to electric strikes and contacts
Lines to the RS-485 devices
Coaxial line to the detection units