7.2 Reset the device to factory settings
Factory
Reset
State
The Reset button carries the name 'Factory-Reset'.
Procedure ü The voltage supply is switched off.
1. Press the Reset button and hold it down.
2. Switch on the voltage supply.
ð The status of the device is displayed. See the signal ‘Reset the device to factory set-
tings’
3. Release the Reset button after 5 to 8 s. See the signal ‘Reset the device to factory set-
tings’
Note:
If the button is pressed for longer than 10 s, the booting process is aborted.
Signal Signal ‘Reset the device to factory settings’
Time
(s)
Status LED Status upon releasing the Reset button
1
2
3
Flashing yellow
light
The device boots up.
The configuration is retained.
4 Solid yellow light The device boots up.
The configuration is deleted.
5
6
7
8
9
10
Flashing red The device boots up.
The configuration is deleted.
11 Solid yellow light The booting process is aborted.
The data are not deleted.
The device is not operational.
The power supply must be switched off and on again.