User Manual
 PleasedonotattempttomounttheS‐250‐12withintheCoolDomeitself,duetothelargeamountofheatcreatedbythepowersupply,willgreatly
reducethecoolingeffectoftheD2CoolDome’sheatpump.
HighVoltageA/CTypicalConventions,singlephase:
Color Symbol Description
Black L  LineConductor,aka:“Hot”wire
White N  NeutralConductor
Green G
,  GroundWire,ChassisGround
LowVoltageconventions,D/C,directcurrent:
Color Symbol Description
Red V+  Positiveconductor
Black V‐   Negativeconductor
TheoutputoftheS‐250‐12externalpowersupply,canbeadjustedupanddown10%.ItisrecommendedtokeepthevoltageattheD2adjustedtoatleast
11.5vdc,butnomorethan13.0vdc.Byrunningtheenclosurehigherthan13.0vdcmaycauseprematurecomponentfailure.Itisbesttocheckandtunethevoltageat
theCoolDomewithavoltagemeteratthetimeofinstallation,andusetheadjustmentscrew,locatedontheS‐250‐12,totherightsideoftheterminalscrews,toraiseor
lowertheoutputvoltage.
Foralloutdoorwiring,alwaysuseanoutdoorratedwiring,orwiringinweatherratedconduit,outfrompowersupply,intotheCoolDome.Followalllocaland
applicablewiringandsafetystandards.
PleasekeepD/Cwirerunsshort,toreducelowvoltagelinedrop
.Also,thesuggestedwiringgaugetableisprovidedtofurtherpreventlowvoltagelinedrop,
andtoguideyouinselectingtheproperwiregaugeforthedcrunfromthepowersupplytothecooldome.
ItisalwaysadvisabletouseadriplooponallwiringgoingdirectlyintotheD2enclosure,toreducetheriskofwaterenteringanddamaginginternal
components.Allfittingsandsealsmustbefirmlytightenedandsealed,beforeplacingtheD2inservice.
InsidetheD2wehaveprovidedaconvenientScrewcageclampstyleterminalblockstowirethe12vdcpositive(V+),andthe12vdcNegative(V‐)terminal.
Pleasestriptheinsulationoffthelast3/8”ofthewiresandfastenwiringsecurelytoterminal,usingasmallbladescrewdrivertotightenthecagingmechanismonthe
terminalblocks.PleasebeespeciallyattentivetowireusingtheProperPolarity
,soasnottodamagetheinternalcomponents,ordamageyourcamerawithin.
12amps
12VoltsD/CVoltageDropforDotworkzD2CoolDome
Wireguage
InAWG(below)
Distance 
(ft)>> 
1.0 ft  10.0  20.0  30.0  40.0  50.0  100.0 
  4.0 
0.006 
0.062 0.124 0.186 0.248 0.310 0.620 
  6.0 
0.010 
0.098 0.196 0.294 0.392 0.490 0.980 
   AWG 8.0 
0.016 
0.156 0.312 0.468 0.624 0.780 
1.560 
  10.0 
0.025 
0.248 0.496 0.744 0.992 
1.240  2.480 
  12.0 
0.040 
0.400 0.800 
1.200  1.600  2.000  4.000 
  14.0 
0.063 
0.628 
1.256  1.884  2.512  3.140  6.280 
GaugeMultiplier
Vdcdrop/ft
Voltagedrop(vdc)/distance(ft)
Acceptable
 line drop for Wire 
Gauge and Distance     
27