D2 Series Product Instructions

PleasedonotattempttomounttheS25012withintheCoolDomeitself,duetothelargeamountofheatcreatedbythepowersupply,willgreatly
reducethecoolingeffectoftheD2CoolDome’sheatpump.
HighVoltageA/CTypicalConventions,singlephase:
Color Symbol Description
Black L LineConductor,aka:“Hot”wire
White N NeutralConductor
Green G
, GroundWire,ChassisGround
LowVoltageconventions,D/C,directcurrent:
Color Symbol Description
Red V+ Positiveconductor
Black V‐ Negativeconductor
TheoutputoftheS25012externalpowersupply,canbeadjustedupanddown10%.ItisrecommendedtokeepthevoltageattheD2adjustedtoatleast
11.5vdc,butnomorethan13.0vdc.Byrunningtheenclosurehigherthan13.0vdcmaycauseprematurecomponentfailure.Itisbesttocheckandtunethevoltageat
theCoolDomewithavoltagemeteratthetimeofinstallation,andusetheadjustmentscrew,locatedontheS25012,totherightsideoftheterminalscrews,toraiseor
lowertheoutputvoltage.
Foralloutdoorwiring,alwaysuseanoutdoorratedwiring,orwiringinweatherratedconduit,outfrompowersupply,intotheCoolDome.Followalllocaland
applicablewiringandsafetystandards.
PleasekeepD/Cwirerunsshort,toreducelowvoltagelinedrop
.Also,thesuggestedwiringgaugetableisprovidedtofurtherpreventlowvoltagelinedrop,
andtoguideyouinselectingtheproperwiregaugeforthedcrunfromthepowersupplytothecooldome.
ItisalwaysadvisabletouseadriplooponallwiringgoingdirectlyintotheD2enclosure,toreducetheriskofwaterenteringanddamaginginternal
components.Allfittingsandsealsmustbefirmlytightenedandsealed,beforeplacingtheD2inservice.
InsidetheD2wehaveprovidedaconvenientScrewcageclampstyleterminalblockstowirethe12vdcpositive(V+),andthe12vdcNegative(V)terminal.
Pleasestriptheinsulationoffthelast3/8”ofthewiresandfastenwiringsecurelytoterminal,usingasmallbladescrewdrivertotightenthecagingmechanismonthe
terminalblocks.PleasebeespeciallyattentivetowireusingtheProperPolarity
,soasnottodamagetheinternalcomponents,ordamageyourcamerawithin.
12amps
12VoltsD/CVoltageDropforDotworkzD2CoolDome
Wireguage
InAWG(below)
Distance
(ft)>>
1.0 ft 10.0 20.0 30.0 40.0 50.0 100.0
4.0
0.006
0.062 0.124 0.186 0.248 0.310 0.620
6.0
0.010
0.098 0.196 0.294 0.392 0.490 0.980
AWG 8.0
0.016
0.156 0.312 0.468 0.624 0.780
1.560
10.0
0.025
0.248 0.496 0.744 0.992
1.240 2.480
12.0
0.040
0.400 0.800
1.200 1.600 2.000 4.000
14.0
0.063
0.628
1.256 1.884 2.512 3.140 6.280
GaugeMultiplier
Vdcdrop/ft
Voltagedrop(vdc)/distance(ft)
Acceptable
line drop for Wire
Gauge and Distance