Installation Manual
1 
Conduit Guidelines: 
1) If wires, cabling, or conduit are coming at enclosure wire entry level, or above, always create a drip loop.
2) Please use only approved watertight electrical conduit and connectors, IP66 or better, with proper seals and fittings installed & fully seal.
3) Then, after all wire and cables are installed into enclosure, Seal wire entry ports inside of enclosure with any number of commercially 
available sealing putty’s, Silicone Sealant, or similar products that are approved by applicable local and relevant electrical codes.
SHOCK HAZARD! Failure to fully seal enclosure wire and cabling entry ports may lead to shock hazard, 
unsatisfactory product performance, a possibility of damage to electronics in the Dotworkz enclosure product, 
including camera damage, and damage to integrated electronics due to air driven moisture traveling thru the 
conduit, condensing and collecting in the enclosure creating a short circuit hazard. 
Dotworkz does not endorse, nor has it evaluated any of these products. Test products first, and follow all manufacturers’ instructions. 
Follow all applicable electrical and building codes and installation guidelines. End user assumes liability for applicability of these products and 
their effectiveness and incurred liability in using these products.
Electrical Conduit Guidelines
For optimal performance, your Dotworkz Enclosure is designed to be Air & Water Tight to eliminate any 
moisture, dust, and insect damage, safety, performance, reliability, and maintenance related issues.
Use of Electrical Conduit, without sealing the entry ports/ inside wire feeds within Camera Enclosure, will 
subject the inside of your enclosure to possibility of condensation driven moisture, dust, and insect contamination 
hazards. 
Dotworkz has provided each enclosure with two Cable Gland Strain Relief seal ports that fully seal 
enclosure to an IP68 rating, Waterproof and Airtight Seal. To properly seal, only one round cable is used in each 
cable gland port. (Holes on enclosure are 7/8” diameter, ready for standard ½” I.D. NPT connector, or PG13 fittings.)
However, we realize our customers are retrofitting these connectors with electrical conduit fittings. We 
acknowledge this industry customization and installation practice, and would like to guide customers to properly 
install these products.
Humid Air 
Condensing to Water
FORCES AT WORK IN ANY UNSEALED, CONDUIT WIRE FEED ENCLOSURE SYSTEM
WARM/MOIST IN UNSEALED CONDUIT MOVES THRU CONDUIT 
FEEDS EXPAND & CONTRACT WHEN CONDUIT HEATS & COOLS 
WITH OUTSIDE TEMPERATURES  
EXPANDING HEATED AIR IS PUSHED INTO ENCLOSURE THEN COOLS & 
CONDENSES, HUMID AIR CONDENSES ON SURFACES INSIDE 
ENCLOSURE
Electrical Putty & Putty Tapes
Silicone Sealants
Foam Sealants (use very sparingly)
Dotworkz  supplies  two  ½”  diameter  foam  conduit  plugs,  that  when  installed,  will  assist  in 
sealing off airflow in conduit feed thru, at cable entry inside of enclosure.  Putty or Sealant can be 
used in conjunction with these plugs, to assure a full seal inside enclosure cable feed entry.