FIREPLACE 2020/2220/2520/2210/2510/2200/2500 INSTALLATION INSTRUCTIONS AND OPERATING MANUAL 2020/2220/2520/2210/2510/2200/2500 1 03.27883.
Table of contents page Foreword 1. Introduction .......................................................................................................................3 2. Safety ...............................................................................................................................3 3. Principle............................................................................................................................4 4. Installation guideline ......................................
Foreword The Installation Manual and Operators Instructions must accompany this appliance. As well as instructions for installation and information about use, you will also find advice concerning safety and maintenance. Please read this booklet carefully before installation and before firing the unit. Save this booklet and pass to any subsequent user who can also profit by it. 1.
3. Principle The Dovre model is designed to provide a fireplace convection system without the need to construct a masonry convection chamber. The principle of operation is that the cooler air from the lower part of the room is drawn under the base of the inner cast iron unit. Warm air is produced from the inner cast iron surfaces of the appliance and this warm air develops between the surfaces of the steel convection case and the outer surfaces of the cast iron combustion chamber.
4. Installation guideline 4.1. Preparatory measures The fireplace should be hermetically connected to a well-functioning chimney, sufficiently enclosed to keep combustible materials (floor and walls) at a distance, and should be installed in a room with sufficient ventilation. Please inform about national or local norms and regulations concerning this subject. Your distributor will give y ou the necessary advice.
The same is true for a cover plate or exhaust hood on top of the chimney. The exhaust hood must not narrow the chimney's outlet and should be designed in a way that wind will not hinder, but promote the smoke flow. • Especially if the flue runs through unhe ated rooms or outside the house, further insulation is necessary. Metal chimneys, or parts of the chimney outside heated rooms should always have double -walled, insulated flues. The part of the chimney outside the roof should always be insulated.
Convection air may be led to arrive from both the room and outside (other room, cellar, exterior) to the bottom side of the fireplace. In case convection air is supplied (directly or indirectly) from outside, it may also be useful as a supply of fresh air for combustion. At any rate, assure proper home air management and sufficient air supply into the room.
4.1.4. Combustible material round the fireplace Within the radiation area of the fireplace Assure a distance of at least 80 cm between the opening of the fireplace and combustible material. That distance may be reduced to 40 cm if the combustible material is sufficiently shielded and well ventilated. Outside the radiation area of the fireplace Assure a distance of at least 5 cm between the mantle built around the fireplace and combustible material.
4.2.3. Fitting frame surround The decorative frames, 3 and 4 sides versions are fitted to the applaice after installation. Ensure that sufficient space is allowed to both sides of the recess. 2020/2220/2520/2210/2510/2200/2500 9 03.27883.
4.2.4. Assembling the “cold handle” Assemble the different parts of the handle, I.e. a screw M8x50, a wooden handle and a nut, as indicated on the sketch. 4.2.5. Electrical connection For protection, the unit must always be connected to power. The appliance is supplied with a speed control to vary the running speed of the fans. This can be left trailing or fitted o the wall mounting supplied. 2020/2220/2520/2210/2510/2200/2500 10 03.27883.
4.3. Installation The appliance is designed to be built into a new or existing chimney breast installation to provide space heating by radiant an convected heat. 4.3.1. To be built into a new chimney Build the new fire place around the appliance ensuring that no materials are built onto the appliance.
4.4. Finishing When the appliance is installed in the right place, its connection with the chimney made airtight, and the masonry mantle completely mounted, all loose parts are installed in the appliance. Your fireplace is now ready to be used. Depending on the materials used for mounting, it is recommended to wait for some time until all masonry is dry before lighting a fire. Attention: never light a fire with the inner plates or refractory stones removed. 4.5.
Chimney Combustible ceiling Refractory cement or special connector Opening against eventual pressure buildup Isolation (min 5 cm) Extra opening for ventilation fireplace Fireproff wall min 10 cm Stainless steel pipe Insulation (if necessary) Combustible wall Canvection air outlet Convection air (min 15 mm) Convection air inlet Fireproof floor Combustible floor Example of fireplace installation within combustible material 2020/2220/2520/2210/2510/2200/2500 13 03.27883.
Existant chimney Extra opening for ventilation firepalce Refractory cement or special connector Existant fireplace Opening against eventual pressure builup Convection air outlet Ventilation: min 15 mm) Convection air inlet Example of installation in an existante fireplace 2020/2220/2520/2210/2510/2200/2500 14 03.27883.
5. Instructions for use 5.1. Fuel The only suitable fuels for this stove are wood, brown coal briquettes and charcoal (when you use a coal-basket). No other fuels are allowed to be burnt, as they can inflict serious damage to your stove. Do not burn any tre ated wood either, such as scrap wood, dyed wood, impregnated or preserved wood, plywood or chipboard.
glowing enough, you can put the logs, the charcoal or the brown coal briquettes on the fire. 5.3. Burning wood Always keep the stove doors tightly closed. Never let the doors open when the fire is burning. Add extra fuel when necessary. Never add too much fuel. It is best to fill the stove for one third and to top it up on a regular basis. Always open the filling door slowly and for a short space of time. Before filling up, the charcoal bed should be carefully spread open.
Before adding some extra coals, use the shaker grate or the supplied shovel, and shake till the glowing parts fall into the ash plate; then add the coals. After a few minutes, add some more coals until you can only see the glow of the previous filling. When the fire basket or the cast-iron plate fins are red-hot, you are heating too intensely. 5.5. Ash removal If your fireplace is equipped with an ashtray (optional), it must be emptied before the ashes reach the lower edge of the combustion grid.
6. Maintenance It takes only little effort to keep your appliance in good condition. Regularly check whether the sealing cord still closes the doors tightly enough. Minor paint damage can be touched up with a can of spray paint. Your dealer can supply you with the correct spray product. During the first use after repainting your unit might give off some slight odour. However, this will disappear quickly. The glass can be cleaned with a number of glass cleaning products available on the market.
2020/2220/2520/2210/2510/2200/2500 19 03.27883.100 9.2 g/s 320 °C Flue gas mass flow Flue gas temperature 0.14 mbar 80 % Efficiency Minimum draught 0.10 % Hout Bois Wood Holz Kolen Charbon Coal Kohlen 0.14 mbar 360 °C 9.7 g/s 76.4 % 0.09 % 79 % 0.05 % 0.14 mbar 360 °C 9.0 g/s 78.1 % 0.10 % Hout Bois Wood Holz 0.14 mbar 360 °C 12.3 g/s 71.1 % 0.
Annex 2 : Dimensions 2500 2200 2020/2220/2520/2210/2510/2200/2500 20 03.27883.
2210S 2510S 2220 2520S 2020/2220/2520/2210/2510/2200/2500 21 03.27883.
2510D 2020S 2520S/2/3 2020/2220/2520/2210/2510/2200/2500 22 03.27883.
CE-conformiteitsverklaring Declaration de conformité CE EC Declaration of conformity Konformitätserklärung CE Notified body: 1625 Wij, Nous, We, Wir, Dovre nv Nijverheidsstraat 18 B2381 Weelde verklaren bij deze dat de inzithaarden 2020; 2220; 2520;2210;2510; 2200; 2500 conform zijn volgens de EN 13229. déclarons que les foyers 2020; 2220; 2520;2210;2510; 2200, 2500 sont conforme au norme EN 13229. declare that the fireplaces 2020; 2220; 2520;2210;2510;2200; 2500 are in conformity with the EN 13229.