Operation Manual

9. Declared performance:
The harmonised norm EN 13240 :2001/A2 :2004/AC :2007
Essential characteristics
Performance
Wood
Performance
Brown coal
Performance
Coal
Fire safety
Fire resistance A1 A1 A1
Distance from combustible material
(minimum distance in mm)
Rear: 100
Side: 100
Rear: 100
Side: 100
Rear: 100
Side: 100
Risk of glowing particles falling out Conform Conform Conform
Emission of combustion products
CO: 0.10%
(13%O
2
)
CO: 0.06%
(13%O
2
)
CO: 0.04%
(13%O
2
)
Surface temperature Conform Conform Conform
Electrical safety - - -
Ease of cleaning Conform Conform Conform
Maximum operating pressure - - -
Flue gas temperature at nominal output 295 °C 289 °C 272 °C
Mechanical resistance
(weight carry of chimney)
Not determined Not determined Not determined
Nominal output 7 kW 7 kW 8 kW
Efficiency 78.3 % 75.4 % 76.4 %
10. The performance of the product described in points 1 and 2 conform with the performance reported
in point 9.
This performance declaration is supplied under the exclusive responsibility of the producer specified
in point 4:
26/08/2013 Weelde
Tom Gehem
CEO
Subject to change because of technical improvements
5