Operation Manual

Model 2500 / 2510 / 2520 / 2620
Model 2500 2510 2520 2620
Nominal output 10 kW 10 kW 10 kW 10 kW
Flue connection (diameter) 150 mm 150 mm 150 mm 150 mm
Weight 150 kg 180 kg 160 kg 160 kg
Recommended fuel Wood Wood Wood Wood
Fuel property, max. length wood 50 cm 50 cm 50 cm 50 cm
Electrical connection 230 V, 50 Hz, 0.5 A
Fuel Wood
Brown coal bri-
quettes
Anthracite coal
Mass flow of flue gasses 9.2 g/s 9.7 g/s 8.1 g/s
Temperature increase measured in the
measuring section
264 K 318 K 314 K
Temperature measured at appliance exit 320 °C - -
Minimum draught 14 Pa 14 Pa 14 Pa
CO emission (13%O
2
) 0.10 % 0.09 % 0.05 %
NOx emission (13% O
2
) 52 mg/Nm³ - -
CnHm emission (13%O
2
) 21 mg/Nm³ - -
Particulate emission 16 mg/Nm³ - -
Efficiency 80.0 % 76.4 % 79.0 %
24
Subject to change because of technical improvements