Technical data
Installation guideline
Preparatory measures
The replace  should be  hermetically connected  to a  well-functioning chimney,  sufciently 
enclosed to keep combustible materials (oor and walls) at a distance, and should be installed 
in a room with sufcient ventilation.
Please inform about national or local  norms and regulations concerning this subject. Your 
distributor will give you the necessary advice.
You can also consult the re department and/or an insurance company about specic demands 
or regulations.
Please read the technical specications under cover in this manual before installing the ap-
pliance.
The chimney
The chimney (the ue) has a double function:
It draws air, that is necessary for good combustion, into the stove.
It functions as an exhaust pipe for combustion gases via thermal or natural draught. Ther
-
mal draught is caused by the difference in heat between the air in- and outside the ue. 
The heated air in the ue is lighter than the colder air outside the ue and consequently 
rises up, along with the combustion gases. Natural draught is caused by environmental 
phenomena, such as wind.
It is prohibited to connect several heaters to one chimney (for instance the central heating 
boiler), unless local or national regulations allow this.
Please check  which  chimney is  to be  used for the  stove you  purchased and whether  your 
chimney is appropriate  for this  specic usage. You should consider  an expert’s opinion  on 
this matter.
The chimney should meet the following conditions:
The ue should be made of reproof material. Ceramic or stainless steel is re-commen-
ded.
The chimney should be airtight and thoroughly cleaned and should guarantee a sufcient 
draught (a draught or negative pressure of 15 to 20 Pa is ideal under normal circumstan
-
ces).
It should run as vertically as possible. Changes in direction or horizontal segments will 
disrupt the  smoke  ow  and  may  cause  soot  to  cumulate  inside  the  ue  (and  clog  the 
ue!).
The chimney’s inside dimensions must not be too large in order to prevent the smoke 
from cooling off too much. For recommended chimney dimensions, see the technical 
specication under cover. Larger dimensions can be used if the ue is well insulated.
•
•
•
•
•
•
30










