Operating Instructions and Installation Instructions

9. Declared performance:
The harmonised norm EN 13240:2001/A2 ;2004/AC :2007
Essential characteristics Performance Wood
Fire safety
Fire resistance A1
Distance from combustible material
Minimum distance in mm
Rear: 300
Side: 500
Risk of glowing particles falling out Conform
Emission of combustion products CO: 0.18% (13%O
2
)
Surface temperature Conform
Electrical safety -
Ease of cleaning Conform
Maximum operating pressure -
Flue gas temperature at nominal output 247
Mechanical resistance (carrying weight of chimney) Not determined
Nominal output 4.9 kW
Efficiency 79.5%
10. The performance of the product described in points 1 and 2 conform with the performance reported
in point 9.
This performance declaration is supplied under the exclusive responsibility of the producer specified
in point 4:
01/10/2013 Weelde
Tom Gehem
CEO
Due to continuous product improvement, the supplied appliance specifications may vary from the description in
this brochure without prior notice having been given.
DOVRE N.V.
Nijverheidsstraat 18 Tel : +32 (0) 14 65 91 91
B-2381 Weelde Fax : +32 (0) 14 65 90 09
Belgium E-mail : info@dovre.be
Subject to change because of technical improvements
5