Operating Instructions and Installation Instructions

09-20021-015
2
1
Connecting to the rear
For a connection to the rear, the position of the con-
nection collar needs to be changed. The connection
collar is attached with 2 M8 nuts (key 13). Proceed as
follows:
1. First remove the baffle plate.
2. Unscrew the nuts and remove the connection col-
lar.
Check that the sealing tape on the contact sur-
face is not damaged. Replace the sealing tape
if it is damaged.
3. Place the connection collar turned 18 with
respect to its original position; see next figure.
09-20021-016
2
1
4. Fit the connection collar with the 2 M8 nuts.
5. Replace the baffle plate.
Preparing the outside air
connection
If the appliance is installed in a room with insufficient
ventilation, you can install the outside air connecting
kit to the appliance.
The air supply tube is 100 mm in diameter. If the tube
is smooth, it may be no longer than 12 metres. If
accessories such as bends are used, the maximum
length (12 m) must be reduced by 1 m for each access-
ory used.
Outside air connection via the wall
1. Make an opening in the wall (see the appendix,
"Measurements", for the correct position of the
opening).
2. Close the air connection hermetically to the wall.
Installing and connecting
1. Position the appliance in the correct place, and
make sure it is level. The appliance is designed
with adjustable feet, which may already be moun-
ted on the appliance or be included. Use these
adjustable feet so that the appliance can be placed
perfectly level.