Installation Guide
FROTHPAK
™
Two component quick-cure
Polyurethane Foam Insulation
Manufacturer’s Insulation Fact Sheet
Dow Building Solutions
(1) The theoretical yield has become an industry standard for identifying certain sizes of two-component
kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into
account the loss of blowing agent or the variations in application methods and types.
Table 1: Sizes and Theoretical Yields for FROTHPAK
™
Foam Insulation
Product Theoretical Yield,
(1)
board ft
Kits
FROTHPAK™ 200 200
FROTHPAK™ 620 620
Refillable Cylinders
FROTHPAK™ 17 (gal) 2,060
FROTHPAK™ 27 (gal) 3,240
FROTHPAK™ 60 (gal) 6,860
FROTHPAK™ 120 (gal) 15,430
FROTHPAK™ 350 (gal) 43,890
Table 2: Typical Physical Properties of FROTHPAK
™
Foam Insulation
These properties are typical but do not constitute specifications.
Property and Test Method Value
Flame Spread/Smoke Developed,
(1), (2)
ASTM E84/UL 723 25/350
Nominal Density, ASTM D1622, lb/ft
3
1.75
Thermal Resistance
(3)
per inch, ASTM C518, ft
2
•h•°F/Btu,
R-value, min. *
Initial
Aged 90 days at 140°F – 1.0"
Aged 90 days at 140°F – 2.0"
6.6
5.4
(when sprayed
as 1" thickness)
11 .2
(R5.6/in. when
sprayed as 2" thickness)
Air Leakage,
ASTM E283, cfm/ft
2
@ 1.57 psf
ASTM E2178, L/s/m
2
@ 75 Pa
0
0
Water Vapor Permeance, ASTM E96
perm @ 1" thick
perm @ 2" thick
3.9
2.0
Water Absorption, ASTM D2842, % by volume 2.17
Dimensional Stability, ASTM D2126, % volume change
100°F/100% RH @ 1wk
100°F/100% RH @ 2wks
158°F/100% RH @ 1wk
158°F/100% RH @ 2wks
-40°F/amb RH @ 1wk
-40°F/amb RH @ 2wks
158°F/amb RH @ 1wk
158°F/amb RH @ 2wks
4.6
5.0
6.5
5.1
0.9
0.9
3.1
2.3
Compressive Strength, ASTM D1621, lb/in
2
, parallel 21.1
Flexural Strength, ASTM C203, lb/in
2
, parallel 22.7
Tensile Strength, ASTM D1623, lb/in
2
, parallel 26.7
Shear Strength, ASTM C273, lb/in
2
, parallel 16.7
Maximum Service Temperature, °F 240
(1) Tested at 2" thickness, full coverage.
(2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other
material under actual fire conditions.
(3) R means resistance to heat flow. The higher the R-value, the greater the insulating power.
* See Read This Before You Buy on Page 2
FROTHPAK
™
Foam Insulation is a two component quick-cure polyurethane foam insulation. This product is