Owner's manual

Figure 1
installation information . commercial . united states
Installation Procedures for THERMAX
Light Duty Insulation on Tilt-up Walls
®™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
*International Energy Conservation Code (IECC) at www.energycodes.gov and American Society of Heating, Refrigerating and Air-Conditioning Engineers at www.ashrae.org
THERMAX
Light Duty Insulation,
when installed on the interior of
tilt-up concrete walls, enhances the
building’s thermal performance and
moisture management and helps meet
continuous insulation requirements
mandated by energy efficiency codes
and standards, such as IECC and
ASHRAE 90.1.* The product can
be installed exposed to the interior
without a thermal barrier.
THERMAX
Light Duty Insulation
is lightweight and easy to install and
can be adhered directly to concrete
or masonry walls. It consists of a
glass-fiber-reinforced polyisocyanurate
foam core laminated with a 1.25
mil embossed white acrylic-coated
aluminum facer on one side and
1.25 mil embossed aluminum on
the other side. The facers make it a
durable choice for use in light-impact
areas. It can be pressure-washed up to
1,000 psi with a 15-degree or greater
spray tip (at minimum 3' distance).
MATERIALS CHECKLIST
• THERMAX
Light Duty Insulation
(code-approved thickness at
minimum)
• Utilityknifeorsmallhandsaw
• Straightedge
• Measuringtape
• Pencil
• Pneumaticnailer(orequivalent)
• PVC(polyvinylchloride)interlocking
system (Figure 1)
• Self-impalingnails/fastenersand
1.25" diameter (min.) plastic washers
• Construction-gradeadhesive
• Silicone,polyurethaneorbutyl
sealant (Table 1)
• Safetyglasses
INSTALLING THERMAX
LIGHT DUTY INSULATION
1. Install THERMAX
Light Duty
Insulation boards along the bottom
perimeter of the interior walls by
applyinga3/8" bead on the back
side of boards at 5' horizontally.
2. Applya3/8" bead of polyurethane
or butyl caulk to the top of each
board and around each cut pen-
etration (joist pockets, conduits,
cutouts, etc.).
3. InstallPVCinterlockingsystem
verticallywithself-impalingnails/
fasteners and washers (Figure 1).
4. Fastennails/fastenersandwash-
ers through front face of insulation
board at 5' o.c. vertically.
5. Applya3/8" bead of sealant to
the bottom flange of all J-Channel
molding (Figure 2).
Tilt-up Wall with THERMAX™ Light Duty Insulation
TABLE 1: RECOMMENDED SEALANTS FOR USE WITH
THERMAX
LIGHT DUTY INSULATION
MATERIAL RECOMMENDED SEALANT
Silicone Dow Corning 790 Silicone Building Sealant
Polyurethane SikaSikaex-201USPolyurethaneSealant
Polyurethane Schnee-MoreheadPermathaneSM7108PolyurethaneSealant
Butyl TremcoVulkem116Sealant
PVC Strips

Summary of content (2 pages)