Instructions / Assembly

Please read and save these instructions. Read carefully before installation, operate or maintain the product described. Protect yourself and others by observing all
safety information.
Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Plug-In Self-Regulating Heating Cables
Product Introduction
These heating cables provide pipes, roof and gutter systems protection from damage due to
freezing, and can be used in residential and commercial applications. The cables automatically
adjust heat output according to the ambient temperature conditions. Under cooler conditions the
heat output increases, and as the temperature rises the output decreases to save on energy.
The cables operate on 120V / 240V and are available in various pre-assembled lengths.
Features
-
Pre-assembled cable lengths include
a 6ft power cord and plug
-
Suitable for plastic or metal pipes,
gutters and downspouts
-
Ease of installation, as the cable
can be overlapped without the risk
of becoming overheated or burnt.
1.
Installation must be in compliance
with National Electrical Codes (NEC).
2.
Use 30 mA ground fault protection on
each heating cable branch circuit for
maximum protection.
3.
Use only
re-resistant insulation,
such as
berglass or preformed
foam. Do not embed heating cable
in the insulation.
4.
Use 1/2
to 1
berglass tape or
plastic cable ties when attaching
cable to pipe. Do not use wire or
metal clamps.
Speci
cations
General Safety Information
Read and understand all instructions in this
manual and the following installation
instructions and Safety Warnings. Electrical
cables, if not installed correctly or are
damaged, can present a re, shock and
arcing
hazard.
5.
Before installing or servicing, ensure
that all power to circuits is OFF.
6.
Do not twist cable during
installation.
7.
Do not install heating cable under
roo
ng material.
8.
Do not expose cable to
temperatures above 150
°
F, as this
will damage the cable.
9.
Do not use extension cords.
10.
Save all instructions for future
reference.
Do not use damaged heating
cables, power cord or plug.
Remove and replace immediately
to prevent a re, shock, or arcing
hazard.
Cable #
Model No.
length(ft)
Volt(V)
On Pipe
@50°F / 10°C
On Pipe
@5°F / 40°C
In-Ice water
@32°F / 0°C
A
DR-9RC1006
6
120V
48
54
72
B
DR-9RC1012
12
120V
96
108
144
C
DR-9RC1018
18
120V
144
162
216
D
DR-9RC1024
24
120V
192
216
288
E
DR-9RC1050
50
120V
400
450
600
F
DR-9RC1075
75
120V
600
675
900
G
DR-9RC1100
100
120V
800
900
1200
H
DR-9RC1125
125
120V
1000
1125
1500
I
DR-9RC2200
200
240V
1600
1800
2400
J
DR-9RC2250
250
240V
2000
2250
3000
Operating Instructions & Parts Manual
DR-9RC 120V / DR-9RC 240V
120V