Full Product Manual
12
Ambient temperature is regulated by adjusting the thermostat to a
desired position. Allow the unit to operate and warm up the room.
When the desired temperature is reached, turn the control knob
counterclockwise until the heater turns off. This is your ideal setting.
The heater will start automatically when the room temperature
drops below this set point, and will turn off when the set point is
reached.
To turn off the heater, switch off the circuit breaker. The
circuit breaker serves as the only means of disconnecting
power from the heater.
This heater includes a visual alarm to warn that parts of the
heater are becoming excessively hot. If the alarm flashes,
immediately turn the heater OFF and inspect for any objects on,
in, or adjacent to the heater that may cause high temperatures.
DO NOT OPERATE THE HEATER WITH THE ALARM
FLASHING. To reset the heater, switch the circuit breaker OFF,
and wait five to ten minutes for the unit to cool down before
turning the heater on again.
How to install Wall Thermostat. (DR-001 Not Included.)
1. Install the Thermostat Outlet Box to the wall. Open the knock-
out on the right.
2. Run line voltage wires to the thermostat location via the
knock-out. Connect the wires as below image: