54 53 55
Cleaning the sunshower and the
acrylic plates
Use a moist cloth to clean the sunshower . The acrylic plates
should also be cleaned at regular intervals. Use only sol-
vent-free, non-caustic and non-aromatic cleaning agents.
To remove the acrylic plates, pull each plate forward from
its position, gripping the profile bars on the side (49) from
behind as shown in Fig. 30. Bend the plate (50) slightly
toward the inside. Then press the plate down and out of
the mounting frame grooves on the sides. The plate can
now be cleaned on both sides.
Replacing UV tubes and starters
To replace tubes and starters, first remove the acrylic
plates as described above.
The UV tubes in your tanning system must be replaced
after a certain number of operating hours.
The effective service life of the UV low-pressure tubes is
about 500 hours. Please ensure that only original
replacement parts are used when replacing tubes and
starters. Replacement parts can be ordered from
customer service or your local dealer. Please indicate
the system number (see ID plate). This applies to orders
for all replacement parts.
UVA low-pressure tubes (53) are removed/inserted by
turning them 90! in their sockets (54) both above and
below and pulling them forward. When inserting new
tubes, please ensure that the contact pins on the tubes
are fitted properly into the sockets.
After cleaning, replace each plate in the following manner:
Set the lower edge of the plate on the pin (51), grip the
side profile bars and press the outer edge of the plate
(52) against one edge of the mounting frame.
Then bend the plate slightly toward the inside and press
until the opposite edge locks into place on the other edge
of the mounting frame. Fig. 31.
Technical Specifications
Tan Can 4000
Lamp tubes: 33 x 100 W UVA reflectorlamps
30 x 25 W spaghettilamps
Nominal power output: 4700 W
Circuit breakers: 3 x 16 A
Nominal voltage: 3N AC 400 V
Power cable: 5 x 1,5 mm²
Dimensions:
Outside dimensions: Æ 1.1 m, height 2.45 m
Inside dimensions: Æ 0.88 m, height 2 m
Exhaust hose: Æ 300 mm
System exhaust configuration
Exhaust air should be removed from your sunshower via
a hose. Please take the following points into account with
regard to the configuration of the exhaust system.
Outside temperature has a considerable impact on
system operation. Ideally, outside temperature should
be 28! with a relative humidity of 70%. Use only 300-mm
hose for the exhaust line. Ideally, exhaust hose should
lead in a straight line up and away from the cell. Bends in
the hose generate air-flow resistance. Avoid 180! bends
in all cases. Given a straight exhaust line configuration,
exhaust hoses can be as long as 2 m without the need
for an additional blower unit. If the exhaust line is longer
than 2 m or has bends, the addition of an auxiliary blower
unit is recommended in order to ensure effective exhaust
air removal. Hose output diameter should not be reduced
at any point in the exhaust line, as this may result in air
blockage.
Starters (55) are located at the upper ends of the tubes
and are removed/inserted by turning them 90° and out
of their sockets. Fig. 32.
Lamp tubes: 48 x 160 W UVA reflector tubes
Nominal power output: 8500 W
Circuit breakers: 3 x 16 A
Nominal voltage: 3N AC 400 V
Power cable: 5 x 1.5 mm²
Dimensions:
Outside dimensions: Æ 1,1 m, height 2,45 m
Inside dimensions: Æ 0,88 m, height 2 m
Exhaust hose: Æ 300 mm
Tan Can 8000