Installation manual

UV Well Water
FILTER
INSTALLATION MANUAL AND OWNER’S GUIDE
Model PC UVS2000
Pure & Clear
Pure & Clear UV Well Water Filter Model PC UVS2000
1211
damage (i.e. nicks or scratches). Replace
damaged “O” Rings.
CAUTION: Use care when cleaning UV head. Do not
get the UV control module or connectors
wet.
7. Clean sumps and heads, inside and outside
with washcloth and cleaning solution. Do
not use abrasive materials.
8. Rinse sumps and heads with clean potable
water.
9. Clean and rinse the Stainless Steel Channel-
ing Sleeve (Item 3) and Sleeve Gasket (Item 4)
shown in Figure 2.
10. Inspect head and sump “O” ring groove area
for damage (i.e. nicks or scratches). Replace
damaged components.
11. Place a small amount of silicone based “O”
ring lubricant on the lter sump “O” ring. In-
stall the “O” ring into the lter sump groove.
DISINFECTION PROCEDURE
CAUTION: WEAR SAFETY GLASSES AND SANITARY
RUBBER GLOVES WHILE PERFORMING
THIS PROCEDURE.
CAUTION: EXCESSIVE CONCENTRATIONS OF
BLEACH WILL DAMAGE PLASTIC AND
RUBBER COMPONENTS. Rinse all parts
that contact bleach thoroughly with clean
potable water.
CAUTION: Read the “WARNINGS on the bleach
container before using.
CAUTION: Handle sanitizing solution carefully.
Avoid contact with unprotected areas.
1. Disconnect system from electrical outlet.
2. Mix sanitizing solution:
a. Mix 237 ml (1 cup) of household bleach
and 237 ml (1 cup) of clean, potable water
in a bucket. Mix the solution well.
CAUTION: Use care when sanitizing UV head. Do not
get the UV control module or connectors
wet.
CAUTION: TIGHTEN SUMPS BY HAND ONLY. Do not
use tools as they will over-tighten and
may damage sump. Take care not to cut
or pinch “O” rings or gaskets. Use sump
wrench for removal only.
3. Add sanitizing solution into system:
a. Add 473 ml (2 cups) of sanitizing solution
to the sump that contains the UV lamp.
4. Slowly open the feed water supply valve.
5. Open all downstream faucets. Keep faucets
open until a chlorine smell is detected at
each faucet, then close faucets.
NOTE: Water lines downstream from UV housing
must be disinfected to destroy any bacteria
that might remain in the pipes.
6. Verify disinfection solution has reached every
water outlet downstream of UV system.
Solution must remain in the system for at
least four hours.
7. Open outlet valve and let water ow for 5
minutes to ush disinfection solution from
the water lines.
ROUTINE MAINTENANCE FILTER
REPLACEMENT PROCEDURE
1. Perform Cleaning Procedure (Page 10, steps
1-11).
NOTE: Do not remove protective plastic bag from
lters. Open bottom of bag only enough to
expose bottom of lter.
NOTE: Refer to Exploded Schematic to ensure each
lter is installed in the correct position.
2. Install the lters into the appropriate sump.
Hold lter by its protective plastic bag and
insert the lter into the sump.
CAUTION: TIGHTEN SUMPS BY HAND ONLY. Do not
use tools as they will over-tighten and
may damage sump. Take care not to cut
or pinch “O” rings or gaskets. Use sump
wrench for removal only.
3. Slide bag from lter and discard. Replace
each sump as each lter is installed.
4. Plug system into electrical outlet. Turn on
water supply and check for leaks. Flush
system for several minutes to remove carbon
nes.
ROUTINE MAINTENANCE UV LAMP
REPLACEMENT PROCEDURE
NOTE: Refer to the system assembly and activation
procedures to identify specic components
matching the descriptions shown in this
procedure.
1. Disconnect system from electrical outlet.
2. Shut feed water supply valve and open
downstream faucet to relieve system
pressure.
CAUTION: Do not attempt to remove sumps until
water ow stops. This reduces pressure
inside the system so sumps may be safely
removed.
CAUTION: Use care when sanitizing UV head. Do not
get the UV control module or connectors
wet.
3. Remove sump from UV head and set aside.
CAUTION: Do not touch Quartz Sleeve or UV lamp
with bare hands. Fingerprints will reduce
the eectiveness of the light.
WARNING: Do not attempt to remove Quartz Sleeve.
Damage to system and personal injury
may occur if the sleeve is removed
incorrectly. Contact Mercola.com if
Quartz Sleeve is broken or needs
replacement.
4. Clean Quartz Sleeve carefully using vinegar
to remove hardness. Do not use abrasive
materials. Rinse sleeve thoroughly with clean
potable water. Replace any sleeve that is
damaged or that will not come completely
clean.
5. Gain access to UV lamp:
a. Remove UV Control Module (Item 10)
from Mounting Bracket (Item 6) by
removing four screws (Item 11).
6. Remove UV lamp from system being careful
not to break UV lamp or dislodge Quartz
Sleeve:
a. Remove UV control module with UV lamp
by gently lifting control module straight
up from mounting bracket. Grasp UV
lamp rmly and remove lamp from the
four-pin socket.
NOTE: The inside of Quartz Sleeve must be
completely dry before installing the
replacement UV lamp.
NOTE: Hold replacement UV lamp by the ceramic
ends only. Do not touch the glass. Clean
glass with isopropyl alcohol if necessary.
7. Install the replacement UV lamp by reversing
steps 5 and 6 of this procedure.