User Manual

74 Dräger X-zone 5500
Key assignment of the Dräger X-zone 5500
19 Key assignment of the Dräger X-zone 5500
20 Status LED overview
Battery LED
(Indicates the battery status.)
Communication LED
(Indicates the connection status if several devices are coupled via wireless connection or communication cable.)
The following key functions refer to the keys of the Dräger X-zone 5500.
Action Meaning
Pressing key once
Acknowledges device defects and pre-alarms.
Pressing and holding key for 3 sec
Switch from OFF to STANDBY mode or switching from STANDBY to ON mode.
Pressing and holding and key for 3 sec
Switches to OFF mode.
Pressing key once
On the main device: Expand group/End search run.
Pressing and holding key for 3 sec
On the main device: Reduce group size.
On the group device: Deletes the grouping information.
3 Press the key 3 times
On the main device: Activate group monitoring.
3 sec. press of and 3 x key
On the main device: Provisionally disable group monitoring.
Colour LED status Device mode Meaning
off off OFF mode Device is switched off.
red
on ON/STANDBY mode
Charge less than 33%.
red/green Charge between 33% and 66%.
green Charge greater than 66 %.
red
ON/STANDBY mode
Battery pre-alarm
red
Battery main alarm; Dräger X-zone 5500 switches off after
10 sec.
red OFF mode
Attempt to switch on in OFF mode when the battery is empty (on
for 10 s).
red
ON/STANDBY mode
in charging cradle
X-zone 5500 is charging, charge less than 33%.
red/green X-zone 5500 is charging, charge between 33% and 66%.
green X-zone 5500 is charging, charge greater than 66%.
green X-zone 5500 is fully charged.
Colour LED status Group monitoring Meaning
green on
off/device not grouped
At least 1 other X-zone 5500 coupled via wireless connection or
cable detected.
activated
On the main device: Device connected to group.
On the group device: Device connected to main device.
green provisionally disabled X-zone 5500 connected to group.
red on
Device not grouped
No additional X-zone 5500 coupled via wireless or cable
connection detected.
activated
Alarm on main device: At least one device in the group is not
connected.
Alarm on group device: No connection to main device.
red provisionally disabled
On the main device: At least one device in the group is not
connected.