User's Manual
    www.dragino.com 
LoRaWAN Door Sensor User Manual      13  /  24 
Example Downlink payload setting in TTN V3:   
Type Code 0x01 
If the payload=0100003C, means to control the LDS02’s Keep Alive interval to 0x00003C=60(S) 
Type Code 0x04 
If payload = 0x04FF, it will reset the LDS02.   
Type Code 0x05 
0x05 00: Set uplink to LoRaWAN unconfirmed mode 
0x05 01: Set uplink to LoRaWAN confirmed mode 
Type Code 0xA6 
Example: 0xA601: Clear Counting 
For LDS02: reset both count number and time.  
Type Code 0xA7 
0xA7 01 : Equal to AT+DISALARM=1 
0xA7 00 : Equal to AT+DISALARM=0   
Type Code 0xA8   
Format: 0xA8 aa bb 
aa: 1: Enable ADR; 0: Disable ADR (Same as AT+CADR command) 
bb: set DR (Same as AT+CDATARATE ,only valid after ADR=0) 
Example: 0x A8 00 02 : Set ADR=0 and DR=1 