User's Manual

DragonWave Inc. 24
AirPair 100 UL 24 GHz Product Manual
Required Action Steps
get programmed frequency Displays the programmed frequency.
Sequence:
Get programmed frequency press Enter
The system responds: ( example uses programmed frequency UNL1)
Index TX IF RX IF TX RF RX RF
UNL1 670 2000 24080 24150
Note: All Frequencies in MHz.
get unlicensed frequencies
Rx
Displays the bank of CUSTOM receive (Rx) frequencies available for
use.
Sequence:
get unlicensed frequencies rx press Enter
The system responds: (example uses rx frequencies)
Index RX IF RX RF
CUSTOM1 2070 24080
CUSTOM2 2060 24090
CUSTOM3 2050 24100
CUSTOM4 2040 24110
CUSTOM5 2030 24120
CUSTOM6 2020 24130
CUSTOM7 2010 24140
CUSTOM8 2000 24150
CUSTOM9 1990 24160
CUSTOM10 1980 24170
CUSTOM11 1970 24180
CUSTOM12 1960 24190
CUSTOM13 1950 24200
CUSTOM14 1940 24210
CUSTOM15 1930 24220
Note: All Frequencies in MHz.