User's Manual

DragonWave Inc. 26
AirPair 100 UL 24 GHz Product Manual
Required Action Steps
set unlicensed frequencies
Tx [index]
Sets the frequency to CUSTOM (decoupled) frequencies for the transmit
(tx) direction
Note: the transmit (Tx) and receive (Rx) frequencies must differ by
at least 70 MHz.
Sequence:
set unlicensed frequencies Tx [index] press Enter
where
Tx is the transmit direction.
Index is the index number of the frequency.
The system responds: (example uses custom unlicensed
frequencies)
Index TX IF RX IF TX RF RX RF
CUSTOM 660 1980 24090 24170
Note: All Frequencies in MHz.
get programmed frequency Displays the programmed frequency:
Sequence:
get programmed frequency press Enter
The system responds: ( example uses custom programmed
frequencies)
Index TX IF RX IF TX RF RX RF
CUSTOM 670 2000 24080 24150
Note: All Frequencies in MHz.
get programmed frequency Displays the programmed frequency:
Sequence:
get programmed frequency press Enter
The system responds: ( example uses custom programmed
frequencies)
Index TX IF RX IF TX RF RX RF
CUSTOM 670 2000 24080 24150
Note: All Frequencies in MHz.