User's Manual
DragonWave Inc. 
96 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
View haam status 
Displays the current status of the HAAM setting. Note that HAAM 
cannot be invoked if RLS is enabled. 
Sequence : 
 get haam status press Enter 
The system responds : 
HAAM set to   :off 
Configured HAAM modes: 
 hy50_91_qpsk hy50_159_16qam hy50_205_32qam 
 hy50_250_64qam hy50_296_128qam hy50_364_256qam 
Current running HAAM mode is :hy50_364_256qam 
HAAM manual mode set to :off 
Peer HAAM set to  :on. 
Peer configured HAAM modes:  
 hy50_91_qpsk hy50_159_16qam hy50_205_32qam 
 hy50_250_64qam hy50_296_128qam hy50_364_256qam 
Example system modes shown. 
Enable haam 
This command turns the Hitless Automatic Adaptive Modulation 
(HAAM) option on or off. 
Note that HAAM cannot be invoked if RLS, ATPC or redundancy is 
enabled. 
Sequence : 
 set haam [<on/off>] 
Example: 
 set haam on and press Enter 
The system responds : 
 HAAM is set to on! 
 Change requires a ‘save mib’ and ‘reset system’ 
 Would you like to ‘savemib’ now? Enter Y(yes) or N (no):Y 
 Mib saved successfully. 
 A ‘reset system’ is required for the change to take effect. 