User's Manual
DragonWave Inc. 
102 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
The  CLI  command  set  network 
management  interface  p3  (could 
be p2, p1, or p4 if the management 
is connected to corresponding port) 
configures  the  Horizon  Compact 
Plus  to  only  accept  management 
traffic  on  p3  of  the  system 
connected  through  the  network  to 
the  management  station  (PC).  Full 
management  of  the  near  end  is 
possible.  Management  of  the  far 
end  unit  over  the  radio  link  is  not 
possible. 
The  CLI  command  set  network 
management  interface  dp3 
(could  be  dp2, dp1,  or  dp3  if  the 
management  is  connected  to  p2, 
p1,  or  p3  respectivey)  applied  at 
both  ends  of  the  link,  configures 
the  system  to  carry  in-band 
management  traffic  across  the 
radio  link  to the  far  end, allowing 
full  management  of  both  ends  of 
the  link.  Note  that  there  is  no 
physical  connecton  to  the 
management  overlay  network  on 
the far end of the link. 
When  both  the  near  and  far  end 
Horizon  Plus  units  are  configured 
with  the  same  out-of-band 
management  port  (p3  in  this 
example)  and both  are connected to 
the  management  overlay  network, 
then  a  network  loop  is  established, 
causing network failure. 