Description 
set  radio  loopback  [on  |  off]  <timeout> 
<network> 
 sets the radio loop back[on|off]. If the user doesn't supply 
the  optional  parameter  [network],  then  the  modem  data 
path will be disabled. 
set  radio  transmitter  state  [on  |  off]  [mute 
time (seconds)] 
 allows  user  to  mute/unmute  the  radio  transmitter. 
[transmitter state] is enabled or disabled. 
set radius server host [index] [server addr] 
 sets the host address for server specified by [index]. 
set radius server key [index] [key] 
 sets the shared key for server specified by [index]. 
set  radius  super  user  authentication 
[On|Off] 
 sets  the  Radius  Authentication  Strictness  mode.  OFF: 
Super  User  can  login  using  flash  password.  ON:  No  one 
can login without Radius. 
set redundancy link monitor parameters 
 sets  redundancy link  monitor parameter (both  hsb_1wire 
and hsb_2wire). 
set redundancy link switch parameters 
 sets  redundancy  hard  error  monitor  parameter  for  link 
establishing. 
set redundancy mode 
 allows  the  user  to  set  system  redundancy 
[primary_hsb_1wire  |  secondary_hsb_1wire  | 
primary_hsb_2wire  |  secondary_hsb_2wire  |  primary_x2  | 
secondary_x2 | normal]. 
set  redundancy  override  [primary  | 
secondary | manual | auto ] 
set redundancy standby enet state  
 allows  the  user  to  set  required  action  on  port1  of 
primary_hsb_2wire  or  secondary_hsb_2wire  node  when  it 
enters  standby  state.  Allowed  actions  are  'on',  'off'  or 
'pulse'. 
set redundancy state switch  
 allows the user to force a change in the redundancy state 
when the override mode is 'auto' or 'manual'. The user input 
is  not  stored  in  the  system  and  set  to  off  after  the  state 
change. 
set rls [on/off] | [basic|advanced] 
 sets the RLS mode on|off and optionally basic|advanced. 
set rls link control [on/off] 
 sets the RLS user link enable option.   When this is set to 
'On'  the  user  has  to  explicitly  enable  the  link  after  it 
recovers from a fault 
set rls link enable [on/off] 
 sets the RLS global link enable status,  if on and no link 
error exists the link will be enabled. 
set  rls  link  monitor  parameters  [mk  erred 
blks]  [brk  erred  blks]  [mk  samples]  [brk 
samples]  [mk  sample  time]  [brk  sample 
time] [brk sample rst time] 
 sets the RLS link monitor low-level parameters 
set rls make rsl [make rsl threshold] [rsl mk 
sample time sec] 
 sets  the  RLS  make  RSL  threshold  and  sample  period, 
where:   [make rsl threshold]    : the minimum rsl threshold 
to establish the link   [make rsl sample period]: the time the 
link rsl must be above the threshold                             to 
establish the link. 
set rls port group 
enables the user to configure which port or ports are to be 
monitored and shut down when an RLS event occurs. 