User's Manual
DragonWave Inc. 
162 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
CLI Command 
Description 
set super user 
 allows  the  user  to  change  the  Super  Username  and 
Password. Username and Password cannot be empty. 
set synce forced holdover 
This is a user troubleshooting command which forces the system 
into  holdover  mode  for  a  configurable  timeout  value  (time)  in 
seconds.  The  default  timout  is  30 seconds.  Values  can  be  0  to 
300 seconds. 0 keeps the holdover on indefinitely. 
set synce member port [p3-p8|wp1|wp2|freerun] 
This command allows you to add all the ports that are required to 
handle SynchE into the member port group. Note that in order to 
configure the ports that are to be the primary and secondary clock 
sources,  the  ports  must  first  be  made  part  of  the  member  port 
group. 
set synce mode [off|manual|auto] 
Use  this  command  to  enable  SyncE.  Select  manual  when  you 
want  the  system  to  go  into  holdover  when  the  primary  clock 
source  fails.  If  the  primary  source  recovers,  the  system  will 
automatically switch back to the primary source. Select auto if you 
want  the  system  to  switch  to  the  secondary  clock  source  if  the 
primary clock source fails. In auto the system will not switch back 
to  the  primary  if  the  primary  clock  recovers,  unless  set  synce 
revertive is enabled. 
set  synce  primary  source  [p3-
p8|wp1|wp2|freerun] 
This command allows you to select which port is to be the primary 
clock source. Note that the port must be configured as a GigE port 
(1000 Mbps). Note, also, that ports p1 and p2, being  SFP ports 
cannot be used as a clock source. 
set synce revertive [on|off] [time] 
This command allows you to enable or disable the revertive mode. 
On  a  primary  clock  source  failure  and  provided  that  the  SyncE 
mode is configured for auto, when revertive mode is enabled (on), 
it  allows  the  system  to  automatically  revert  back  from  the 
secondary  to  the  primary  clock  source,  once  the  primary  clock 
source has recovered and  remains stable for  a  selected time in 
seconds. The default time is 10 seconds. 
set  synce  secondary  source  [p3-
p8|wp1|wp2|freerun] 
This command allows you to select the port that will provide the 
secondary clock source.  It will take over from the primary clock 
source  if  the  primary  clock  source  fails.  Note  that  unless  the 
revertive  feature  is  enabled  (set  synce  revertive  on),  if,  after  a 
switch to the secondary clock source,  the primary clock source 
recovers,  the  system  will  not  automatically  switch  back  from 
secondary to the primary clock source. 
set synce wander filter [option1|option2] 
This  command  allows  the  user  to  select  either  Ethernet 
Equipment Clock filter Option 1, or  Option 2. Option 1 would be 
used  in  the  E1  TDM  hierarchy  and  Option  2  in  the  T1  TDM 
hierarchy. 
set syslog forwarding [on|off] 
 set syslog forwarding on or off. Syslog will start forwarding 
messages to specified host when turned 'on' 
set syslog forwarding host [ipAddress] 
 set the syslog forwarding host IP Address. 
set system current speed [speed] 
 sets the current speed in Mbps. 
set system mode [system mode name] 
 sets the system mode. 
set telnet [on|off] 
 enables  or  disables  the  Telnet  Access  to  the  user. 
(Access: Only through Serial Port) 
set traffic statistics [0] 
 clears all traffic  statistics,  including extended statistics  to 