User's Manual
RADIUS Server Authentication 
19 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
Select the port that will be the 
primary (master) 
synchronization clock source 
This command allows you to select which port is to be the primary 
clock source. Note that in order to configure the primary clock source 
port, the port must first be made part of the member port group and be 
configured as GigE (1000 Mbps), or 100BaseT (100 Mbps). Note, also, 
that if port p1 is an SFP port it cannot be used as a clock source.  
Sequence: 
set synce primary source [p1|p2|p3|p4|wp1|freerun]  
Example: set synce primary source wp1 press Enter 
The system responds: 
Synce mode  : off 
Primary clock source : wp1 
Secondary clock source : freerun 
Synce members  : p4,wp1,freerun 
Revertive mode  : off 
Wander filter option  :option2 
Select the port that will be the 
secondary synchronization 
clock source 
This command allows you to select the port that will provide the 
secondary clock source. It will take over from the primary clock source 
if the primary clock source fails. Note that in order to configure the port 
that is to be the secondary clock source the port must first be made 
part of the member port group and be configured as GigE (1000 
Mbps), or 100BaseT (100 Mbps). Note, also, that unless the revertive 
feature is enabled (set synce revertive on), if, after a switch to the 
secondary clock source, the primary clock source recovers, the 
system will not automatically switch back from secondary to the 
primary clock source. 
Sequence: 
set synce secondary source [p1|p2|p3|p4|wp1|freerun] 
Example: set synce secondary source p4 press Enter 
The system reponds: 
Synce mode  : off 
Primary clock source : wp1 
Secondary clock source : p4 
Synce members : p4,wp1,freerun 
Revertive mode  : off 
Wander filter option  :option2 