RADIUS Server Authentication 
21 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
View current SyncE 
configuration 
Use this command to return the current SyncE configursation settings. 
Sequence: 
get synce config press Enter 
The system responds: 
Synce mode  : auto 
Primary clock source : wp1 
Secondary clock source: p4 
Synce members : p4,wp1,freerun 
Revertive mode  : on 
Wander filter option  :option2 
Required for 
troubleshooting only. 
Forcing SyncE into holdover 
mode 
This is a user troubleshooting command which forces the system into 
holdover mode for a configurable timeout value (time) in seconds. The 
default timout is 30 seconds. Values can be 0 to 300 seconds. 0 keeps 
the holdover on indefinitely. 
Sequence: 
set synce forced holdover [on [time]|off] 
Example: set synce forced holdover on 60 press Enter 
The system responds: 
Synchronous Ethernet is put into holdver for 60 sec. 
get synce status press Enter 
The system responds: 
mode: auto 
clock source: wp1 
acquisition status: holdover 
forced holdover: on 
remaining time in forced holdover: 52 sec 