Threshold Alarms 
73 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
View RSL threshold alarm 
settings 
Displays the current settings for the Threshold Alarm for the Receive 
Signal Level (RSL). Once the RSL Value Threshold is reached and 
continues for the Time Limit duration then an alarm is raised. 
Sequence: 
get rsl threshold press Enter 
The system responds: 
RSL threshold set to : <rsl value> dbm 
RSL timelimit set to : <timelimit> secs 
Where 
<rsl value> is the current RSL value in integers, given in dBm. 
<timelimit> is the current time limit that the condition must occur 
before the alarm is raised. Timelimit is in integers, given in number 
of seconds 
Configure RSL threshold 
alarm settings 
Sets the current settings for the Threshold Alarm for the Receive 
Signal Level (RSL). Once the RSL Value Threshold is reached and 
continues for the Time Limit duration then an alarm is raised. 
Sequence: 
set rsl threshold <rsl value> <timelimit> press Enter 
Where 
<rsl value> is the desired RSL value in integers, given in dBm. 
<timelimit> is the desired time limit that the condition must occur 
before the alarm is raised. Timelimit is in integers, given in number 
of seconds 
The system responds: 
RSL threshold set to : <rsl value> dbm 
RSL timelimit set to : <timelimit> secs 
View snr threshold 
Returns the current signal to noise ratio alarm threshold. 
Sequence: 
get snr threshold press Enter 
The system responds: 
SNR threshold set to  : n 
Where n is the current SNR threshold setting 