User's Manual
DragonWave Inc. 
74 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
Configure snr threshold 
Sets the SNR level below which a threshold alarm will be raised. 
Sequence: 
set snr threshold <snr value> press Enter 
Where <snr value> is in dB and between 0 and 30 
The system responds: 
SNR threshold set to : n 
Where n is the new SNR threshold setting 
View bandwidth utilization 
threshold alarm settings 
Displays the current settings for the Bandwidth Utilization Threshold 
Alarm. 
Sequence: 
get bandwidth utilization threshold press Enter 
The system responds: 
Bandwidth utilization threshold set to : <value> % Bandwidth 
utilization timelimit set to : <timelimit> secs. 
Where 
<value> is the current bandwidth utilization value expressed in 
percentage 
<timelimit> is the desired time limit that the condition must occur 
before the alarm is raised. Timelimit is in integers, given in number 
of seconds 
Configure bandwidth 
utilization threshold alarm 
settings 
Sets the values for the Threshold Alarm for the Bit Error Rate (BER) as 
calculated by the Horizon Compact Plus modem. Once the BER 
Value Threshold is reached and continues to remain between the 
Threshold value and the hysteresis value, then an alarm is raised. 
Once the value drops below the hysteresis value then the alarm is 
cleared. 
Sequence: 
set bandwidth utilization threshold <value> <timelimit> press 
Enter 
Where 
<value> is the current bandwidth utilization value expressed in 
percentage 
<timelimit> is the desired time limit that the condition must occur 
before the alarm is raised. Timelimit is in integers, given in number 
of seconds. Default value is 10 seconds 
The system responds: 
Bandwidth utilization threshold set to : <value> % Bandwidth 
utilization timelimit set to : <timelimit> secs. 