User's Manual
DragonWave Inc. 
82 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
set rls link enable [on/off] 
When rls link control is set to on, the data Ethernet port remains in a shutdown state after the 
RLS condition has been cleared.  The Ethernet port is manually re-enabled by issuing the set 
rls link enable on command. The set rls link enable off command disables the Ethernet port. 
Procedure 14-1  
Configure Rapid Link Shutdown Options 
Perform  this procedure  to  configure the Rapid Link Shutdown Options  for the  Horizon Compact Plus 
system.  When RLS is used, the Horizon Compact Plus Port 1 will be set to "down" during modem-to-
modem  communication  failure.    This  feature  allows  a  router  to  select  an  alternate  path  should  the 
modem-to-modem communications fail. 
Note: To perform this procedure, you must have NOC user rights. 
Required Action 
Steps 
login 
Log in as a NOC user. 
View rls 
Displays the state of the Rapid Link Shutdown feature. RLS provides 
the ability to shut down the Horizon Compact Plus Ethernet link (both 
endpoints) during system outages. 
The default is "off". 
Sequence:  
get rls press Enter 
The system responds: 
RLS option is :[off/on]. 
View rls status 
Displays the detailed status of the RLS configuration. 
 Sequence: 
 get rls status press Enter 
The system responds (Example): 
RLS Option:  On Advanced 
Rapid Link Shutdown:  Activated 
RLS Peer Mismatch:   Activated 
Degrade Monitor State:  Activated 
Hard Fault Monitor State: Acitvated 
Make RSL Threshold: OK 
Peer RLS State:  OK 
Radio Interface State: Up 
Network Interface State:  Down 
User Configured Establish FER:  8.82E-07 
Minimum Achievable Establish FER:  3.06E-07 
User Configured Shutdown FER:  1.76E-04 
Minimum Achievable Shutdown FER: 3.06E-06 
User Configured Establish Monitor Time(mSec): 40000 
Actual Establish Monitor Time(mSec): 45517 
User Configured Shutdown Monitor Time(mSec): 3000 
Actual Shutdown Monitor Time(mSec): 4550 