User's Manual
DragonWave Inc. 
84 
Horizon Compact Plus Release 1.0.1    Wireless Ethernet Product User Manual – Volume 2 
Required Action 
Steps 
Configure rls link control 
[on/off] 
Determines whether RLS link control performs automatic recovery or 
requires manual recovery of the Ethernet port. RLS provides the 
ability to shut down the Horizon Compact Plus Ethernet ports (Port 1 
on both endpoints) during system outages. The user can manually 
recover the Ethernet ports through the use of the "set rls link enable 
on" command. 
The default is "off". 
Sequence:  
set rls link control [on/off] press Enter 
The system responds: 
RLS link control is set to [on/off] 
Where 
On means the user must manually recover the Ethernet port 
through the use of the "set rls link enable on" command. 
Off means the Horizon Compact Plus system will automatically 
recover the Ethernet port. 
View rls link enable 
Displays the state of the Rapid Link Shutdown (RLS) link enable 
feature. RLS provides the ability to shut down the Horizon Compact 
Plus Ethernet ports (Port 1 on both endpoints) during system 
outages. 
The default is "off". 
Sequence:  
get rls link enable press Enter 
The system responds: 
RLS link enable is set to [on/off] 
Where 
On means to re-enable the Ethernet port on the modem 
Off means the Ethernet port is not re-enabled. 
Configure rls link enable 
[on/off] 
Manually enables or disables the Horizon Compact Plus Ethernet 
link. This feature requires the rls link control feature to be "on". 
The default is "off". 
Sequence:  
set rls link enable [on/off] press Enter 
The system responds: 
RLS link enable is set to [on/off] 
Where 
On means to re-enable the Ethernet port on the modem 
Off means the Ethernet port is not re-enabled. 