Table No. 2
Trouble Cause Remedy
Cartridge not fed into
chamber. Bolt in front
position, but no shot
fired (no cartridge in
cartridge chamber)
Dirty or faulty
magazine. Faulty
magazine latch
Reload the rifle and
proceed with firing.
Replace the magazine,
if stoppage is
repeated. Transfer the
rifle to the repair
shop, if the magazine
latch is faulty
Misalignment of
cartridge. Cartridge
with its bullet rests
on barrel breech face,
moving parts stop in
middle position
Bent guiding lugs of
magazine side walls
Holding the bolt
support
reloading handle,
remove the misaligned
cartridge and proceed
with firing. If
the stoppage is
repeated, replace the
magazine..
Misfire. Bolt in front
position, cartridge in
cartridge chamber,
hammer released, no
shot fired
Faulty cartridge.
Faulty firing pin or
firing and trigger
mechanism, dirty or
thick lubricant
Reload the rifle and
proceed with firing.
If stoppage is
repeated, inspect and
clean the firing pin
and the firing and
trigger mechanism; if
they are broken or
worn, transfer the
rifle to the repair
shop
Fired case fails to be
extracted. Fired case
in cartridge chamber,
the next cartridge
with its bullet rests
on fired case, moving
parts are in middle
position
Dirty cartridge or
dirty
cartridge chamber.
Dirty or faulty
extractor
or its spring
Retract the bolt
support reloading
handle, and holding it
in the rear position,
detach the magazine
and remove the
misaligned cartridge.
Extract the fired case
by the bolt or by the
cleaning rod and
proceed with firing.
If the stoppage is
repeated, clean the
cartridge chamber.
Inspect and clean the
extractor, then
proceed with firing.
If the extractor is
faulty, transfer the
rifle to the repair
shop